Browsing by Author "Harasym, Dmytro"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Analysis of exergy efficiency and ways of energy saving in air conditioning system for a cleanroom(Publishing House of Lviv Polytechnic National University, 2015) Harasym, Dmytro; Labay, VolodymyrIn modern technologies, which are related to energy transformation, namely in air conditioning systems, important places are occupied by equipment and processes, the objective estimation of value of its energy perfection can be defined only on the basis of analysis of its exergy efficiency. So, reducing the cost of energy consumed by air conditioning systems preconditions the need for its optimization, which can be fully achieved by virtue of exergy analysis that takes into account not only the quantity but also the quality of energy spent. Nowadays cost estimates can’t be the only measure of effectiveness of energy equipment that is using energy resources. Exergy is a physical not an economical criterion and defines its independence from conjectural fluctuations of prices. At the same time, cost parameters don’t allow making long term predicting. The minimum should be defined not by financial costs but exergy losses per unit of received heat. Unfitness of just the financial costs is obvious. Analysis of exergy efficiency of the central straight flow air conditioning system (ACS) for cleanroom, that was gained on its innovation mathematical research model depending on different factors, which have influence on its work was presented in this article, and the ways of energy saving for this ACS was proposed. It was found that temperature difference between inside and supplied air in a room, temperature of inside air which depends on temperature of outside air and coefficient of transformation EER of refrigerator machine of ACS have the biggest impact on exergetic output-input ration of chosen air conditioning system. У сучасних технологіях, пов’язаних з перетворенням енергії, а саме у системах кондиціювання повітря, важливе місце займають обладнання і процеси, об’єктивну оцінку ступеня енергетичної досконалості яких можна встановити тільки на основі аналізу їх ексергоефективності. Отже, зменшення витрат енергії, споживаної системами кондиціювання повітря, диктує необхідність їх оптимізації, що найповніше може бути досягнуто на основі ексергетичного аналізу, який враховує не тільки кількість, але й якість витраченої енергії. Нині вартісні оцінки не можуть слугувати єдиною мірою ефективності енергетичного обладнання, які переробляють енергоресурси. Ексергія є фізичним, а не економічним критерієм і визначає незалежність цього параметра від кон’юнктурних коливань цін. Водночас вартісні показники не дають змогу здійснити довгострокове прогнозування. Визначати мінімум необхідно не грошовими витратами, а витратами ексергії на одиницю виданої теплоти. Непридатність тільки грошових критеріїв очевидна. У статті наведено аналіз ексергоефективності центральної прямотечійної системи кондиціювання повітря (СКП) чистого приміщення, отримано на її інноваційній математичній дослідницькій моделі залежно від різних факторів, що впливають на її роботу, та запропоновані шляхи енергозбереження для цієї СКП. Встановлено, що найбільший вплив на ексергетичний ККД вибраної системи кондиціювання мають різниця температур між внутрішнім і припливним повітрям у приміщенні, температура внутрішнього повітря, залежна від температури зовнішнього повітря, та коефіцієнт трансформації EER прийнятої холодильної машини СКП.Item The estimation of exergy efficiency and exergy losses in air conditioning systems of operating cleanrooms by a Grassmann diagram(Lviv Polytechnic National University, 2015) Harasym, Dmytro; Labay, VolodymyrAn important place in the up-to-date technologies related to energy transformation is occupied by the processes and equipment for which the objective value of energy perfection can be defined only on the basis of the thermodynamic analysis. The simplest method of thermodynamic analysis is the energy method based on the law of energy conservation. It provides the possibility to estimate the absolute and relative energy losses and to reveal equipment and processes with the highest losses. However, this method makes the values of all kinds of energy equal, thermal energy in particular, which is wrong according to the second law of thermodynamics, because any kind of energy can be completely converted into thermal energy, while the reverse process is accompanied by unavoidable losses. An innovative mathematical research model of an existing central straight-flow air conditioning system for operating cleanrooms is presented in this article. The aim of the model is to carry out computer estimation of exergy efficiency of existing air conditioning system and exergy losses of its elements depending on different factors affecting its work. The Grassmann diagram of exergy flows and losses for the existing air conditioning system at an outdoor air temperature of 35 °C has been defined due to this model. У сучасних технологіях, пов’язаних з перетворенням енергії, а саме у СКП, важливе місце займають обладнання і процеси, об’єктивну оцінку ступеня енергетичної досконалості яких можна встановити тільки на основі їх термодинамічного аналізу. Найпростішим методом термодинамічного аналізу є енергетичний, заснований на законі збереження енергії. Він дає змогу оцінити абсолютні і відносні втрати енергії, виявити обладнання і процеси з найбільшими втратами. Однак цей метод прирівнює один до одного цінності всіх видів енергії, зокрема і теплової, що неправильно з позицій другого закону термодинаміки, оскільки будь-який вид енергії може повністю перетворюватись на теплову, зворотний же процес супроводжується неминучими втратами. Використано авторську інноваційну математичну дослідницьку модель впровадженої центральної прямотечійної системи кондиціювання повітря операційних чистих кімнат. Мета моделі – комп’ютерне оцінювання ексергетичної ефективності діючої системи кондиціювання та втрат ексергії в її елементах залежно від різних факторів, що впливають на її роботу. Завдяки цій моделі отримано діаграму Грассмана потоків та втрат ексергії для діючої системи кондиціювання за температури зовнішнього повітря 35 °С.