Browsing by Subject "air conditioning systems"
Now showing 1 - 8 of 8
- Results Per Page
- Sort Options
Item Analysis of exergy efficiency and ways of energy saving in air conditioning system for a cleanroom(Publishing House of Lviv Polytechnic National University, 2015) Harasym, Dmytro; Labay, VolodymyrIn modern technologies, which are related to energy transformation, namely in air conditioning systems, important places are occupied by equipment and processes, the objective estimation of value of its energy perfection can be defined only on the basis of analysis of its exergy efficiency. So, reducing the cost of energy consumed by air conditioning systems preconditions the need for its optimization, which can be fully achieved by virtue of exergy analysis that takes into account not only the quantity but also the quality of energy spent. Nowadays cost estimates can’t be the only measure of effectiveness of energy equipment that is using energy resources. Exergy is a physical not an economical criterion and defines its independence from conjectural fluctuations of prices. At the same time, cost parameters don’t allow making long term predicting. The minimum should be defined not by financial costs but exergy losses per unit of received heat. Unfitness of just the financial costs is obvious. Analysis of exergy efficiency of the central straight flow air conditioning system (ACS) for cleanroom, that was gained on its innovation mathematical research model depending on different factors, which have influence on its work was presented in this article, and the ways of energy saving for this ACS was proposed. It was found that temperature difference between inside and supplied air in a room, temperature of inside air which depends on temperature of outside air and coefficient of transformation EER of refrigerator machine of ACS have the biggest impact on exergetic output-input ration of chosen air conditioning system. У сучасних технологіях, пов’язаних з перетворенням енергії, а саме у системах кондиціювання повітря, важливе місце займають обладнання і процеси, об’єктивну оцінку ступеня енергетичної досконалості яких можна встановити тільки на основі аналізу їх ексергоефективності. Отже, зменшення витрат енергії, споживаної системами кондиціювання повітря, диктує необхідність їх оптимізації, що найповніше може бути досягнуто на основі ексергетичного аналізу, який враховує не тільки кількість, але й якість витраченої енергії. Нині вартісні оцінки не можуть слугувати єдиною мірою ефективності енергетичного обладнання, які переробляють енергоресурси. Ексергія є фізичним, а не економічним критерієм і визначає незалежність цього параметра від кон’юнктурних коливань цін. Водночас вартісні показники не дають змогу здійснити довгострокове прогнозування. Визначати мінімум необхідно не грошовими витратами, а витратами ексергії на одиницю виданої теплоти. Непридатність тільки грошових критеріїв очевидна. У статті наведено аналіз ексергоефективності центральної прямотечійної системи кондиціювання повітря (СКП) чистого приміщення, отримано на її інноваційній математичній дослідницькій моделі залежно від різних факторів, що впливають на її роботу, та запропоновані шляхи енергозбереження для цієї СКП. Встановлено, що найбільший вплив на ексергетичний ККД вибраної системи кондиціювання мають різниця температур між внутрішнім і припливним повітрям у приміщенні, температура внутрішнього повітря, залежна від температури зовнішнього повітря, та коефіцієнт трансформації EER прийнятої холодильної машини СКП.Item Influence of Transformation Coefficient of Refrigerating Machine on Exergetic Efficiency of Air Conditioning System of Operating Clean Rooms(Видавництво Львівської політехніки, 2023-02-28) Лабай, Володимир; Андрейко, Кирило; Labay, Volodymyr; Andreiko, Kyrylo; Національний університет “Львівська політехніка”; Lviv Polytechnic National UniversityЕксергетичний метод є універсальним способом термодинамічного дослідження різноманітних процесів перетворення енергії в енергетичних технологічних системах, до яких належить система кондиціювання повітря для чистого приміщення. Здійснення ексергетичного аналізу для енерготехнологічної системи дає можливість визначити вплив різних елементів її системи на її роботу і завдяки цьому підвищити ефективність роботи енерготехнологічної системи в цілому. Ефективність роботи будь-якої системи кондиціонування залежить від енергоефективності холодильної машини, яка її обслуговує і споживає електроенергію для зменшення теплоти припливного повітря, яке надходить у приміщення. А це означає, що основною метою підбору тієї чи іншої холодильної машини для системи кондиціонування є досягнення максимальної холодопродуктивності за мінімального споживання енергії. У статті використана авторська інноваційна математична модель дослідження впровадженої центральної прямотечійної системи кондиціонування повітря для діючих чистих приміщень. Метою моделі є комп’ютерна оцінка ексергетичної ефективності системи кондиціювання повітря залежно від різних факторів, що впливають на її роботу, зокрема коефіцієнта трансформації EER її холодильної машини. Наведено залежність ексергетичного ККД впровадженої системи кондиціонування повітря для діючих чистих приміщень від коефіцієнта трансформації EER її холодильної машини за різних параметрів зовнішнього та внутрішнього повітря та різниць температур внутрішнього та припливного повітря. Показано, що впроваджена система кондиціонування повітря має переважно використовуватися з вищим коефіцієнтом трансформації EER її холодильної машини та більшою різницею між температурами внутрішнього та припливного повітря за різних температур зовнішнього повітря, що дасть можливість отримати найвищий ексергетичний ККД. Це означає забезпечення найощаднішого економічного варіанта експлуатації впровадженої системи кондиціонування.Item Innovation model for energy effective investigations of air conditioning systems for cleanrooms(Commission of Motorization and Energetics in Agriculture, 2014) Labay, V.; Harasym, D.Innovation mathematical research model of the central straight flow air conditioning system for cleanroom in order to computer’s estimation its energy effective by virtue of exergetic output-input ratio depending on different factors, which have influence on its work, was presented in this article. The dependence of exergetic output-input ratio for chosen air conditioning system on parameters of external air was defined thanks to this model.Item Investigations on the innovation model of exergy effectiveness of air conditioning system for operating cleanrooms(Printing Center of lviv Politechnic Publishing House, 2017-02-14) Дмитро, Гарасим; Лабай, Володимир; Dmytro, Harasym; Volodymyr, Labay; Національний університет “Львівська політехніка”; Lviv Polytechnic National UniversityНині під час експлуатації енерготехнологічних систем (ЕТС), до яких належать системи кондиціювання повітря (СКП), для забезпечення проведення певної технології питання економії паливно-енергетичних ресурсів має першорядне значення. Отже, зменшення затрат енергії, споживаної системами кондиціювання повітря, диктує необхідність їх оптимізації, що найповніше може бути досягнуто на основі ексергетичного аналізу, який враховує не тільки кількість, але й якість затраченої енергії. Розрахунки балансів і різних характеристик ЕТС, зокрема СКП, з урахуванням ексергії дає можливість найпростіше і наглядніше вирішувати безліч наукових і технічних задач. Вони допомагають вилучити часті помилки, які трапляються і пов’язані з ігноруванням якісного боку перетворень. У статті презентовано інноваційну математичну дослідницьку модель чинної центральної прямотечійної системи кондиціювання повітря для операційних чистих кімнат з метою комп’ютерного оцінювання її енергетичної ефективності через ексергетичний ККД залежно від різних факторів, що впливають на її роботу. Завдяки цій моделі отримано залежність ексергетичного ККД ηе чинної системи кондиціювання від різниці температур між внутрішнім і припливним повітрям Δtп= tв – tп.Item The estimation of exergy efficiency and exergy losses in air conditioning systems of operating cleanrooms by a Grassmann diagram(Lviv Polytechnic National University, 2015) Harasym, Dmytro; Labay, VolodymyrAn important place in the up-to-date technologies related to energy transformation is occupied by the processes and equipment for which the objective value of energy perfection can be defined only on the basis of the thermodynamic analysis. The simplest method of thermodynamic analysis is the energy method based on the law of energy conservation. It provides the possibility to estimate the absolute and relative energy losses and to reveal equipment and processes with the highest losses. However, this method makes the values of all kinds of energy equal, thermal energy in particular, which is wrong according to the second law of thermodynamics, because any kind of energy can be completely converted into thermal energy, while the reverse process is accompanied by unavoidable losses. An innovative mathematical research model of an existing central straight-flow air conditioning system for operating cleanrooms is presented in this article. The aim of the model is to carry out computer estimation of exergy efficiency of existing air conditioning system and exergy losses of its elements depending on different factors affecting its work. The Grassmann diagram of exergy flows and losses for the existing air conditioning system at an outdoor air temperature of 35 °C has been defined due to this model. У сучасних технологіях, пов’язаних з перетворенням енергії, а саме у СКП, важливе місце займають обладнання і процеси, об’єктивну оцінку ступеня енергетичної досконалості яких можна встановити тільки на основі їх термодинамічного аналізу. Найпростішим методом термодинамічного аналізу є енергетичний, заснований на законі збереження енергії. Він дає змогу оцінити абсолютні і відносні втрати енергії, виявити обладнання і процеси з найбільшими втратами. Однак цей метод прирівнює один до одного цінності всіх видів енергії, зокрема і теплової, що неправильно з позицій другого закону термодинаміки, оскільки будь-який вид енергії може повністю перетворюватись на теплову, зворотний же процес супроводжується неминучими втратами. Використано авторську інноваційну математичну дослідницьку модель впровадженої центральної прямотечійної системи кондиціювання повітря операційних чистих кімнат. Мета моделі – комп’ютерне оцінювання ексергетичної ефективності діючої системи кондиціювання та втрат ексергії в її елементах залежно від різних факторів, що впливають на її роботу. Завдяки цій моделі отримано діаграму Грассмана потоків та втрат ексергії для діючої системи кондиціювання за температури зовнішнього повітря 35 °С.Item Вплив внутрішніх температури і вологовмісту повітря операційних чистих кімнат на ексергетичний ККД центральної прямотечійної системи кондиціювання повітря(Видавництво Львівської політехніки, 2016) Гарасим, Д. І.; Лабай, В. Й.У сучасних системах кондиціювання повітря важливе місце займають обладнання і процеси, об’єктивно оцінити ступінь енергетичної досконалості яких можна лише на основі їх ексергетичного аналізу. У статті використано авторську інноваційну математичну дослідницьку модель впровадженої центральної прямотечійної системи кондиціювання повітря операційних чистих кімнат з метою комп’ютерного оцінювання її енергетичної ефективності на основі ексергетичного ККД залежно від різних факторів, що впливають на її роботу. Завдяки цій моделі отримано залежність ексергетичного ККД he впровадженої системи кондиціювання від параметрів внутрішнього повітря, а саме температури tв і вологовмісту dв . Встановлено, що вологовміст dв не впливає на ексергетичний ККД hе системи. Показано, що таку систему кондиціювання повітря бажано використовувати за нижчих температур внутрішнього повітря, а саме, наприклад, tв = 25 °С та з якомога найвищою різницею температур між внутрішнім і припливним повітрям Dtп = tв - tп , наприклад, Dtп = 9,0 °С, що дасть можливість отримати найвищий ексергетичний ККД hе = 2,56, а отже, отримати економічно найвигідніший варіант використання впровадженої системи кондиціювання повітря. In the modern air conditioning systems, important place are occupied by equipment and processes, the objective estimation of value of its energy perfection can be defined only on the basis of exergetic analysis. Innovation mathematical research model of the implemented central straight flow air conditioning system for operation cleanrooms in order to computer’s estimation its energy effective by virtue of exergetic output-input ratio depending on different factors, which have influence on its work, was described in this article. The dependence of exergetic output-input ratio for chosen air conditioning system hе on parameters of indoor air, namely temperature tin and moisture content din was defined thanks to this model. It is found, that there is no effect of moisture content din on exergetic output-input ratio hе of the system. It is shown that the implemented air conditioning system should be preferably used at lower indoor air temperatures, namely, for example tin = 25 °С, and at as higher temperature difference between indoor and supplied air DtS = tin - tS as it possible, for example, Dtп = 9,0 °С, that will give the opportunity to gain the highest exergetic output-input ratio hе = 2,56, which means to gain the most advantageous economical variant of exploitation of implemented air conditioning system.Item Ексергетичне обґрунтування та підвищення енергоефективності роботи систем кондиціювання повітря для чистих приміщень(Національний університет "Львівська політехніка", 2018) Гарасим, Дмитро Ігорович; Лабай, Володимир Йосифович; Національний університет «Львівська політехніка»; Радченко, Микола Іванович; Жихарєва, Наталія ВіталіївнаЗдійснено новий підхід до встановлення ексергоощадної експлуатації СКП на прикладі центральних прямотечійних СКП чистих приміщень як з камерою зрошення, так і з рекуперативним повітроохолодником, що ґрунтується на використанні сучасного методу термодинамічного аналізу – ексергетичного. Створено алгоритми та математичні моделі роботи цих СКП та, відповідно, розроблені комп’ютерні програми для здійснення досліджень, що дозволили виконати розрахунково-кількісні експерименти на математичних моделях досліджуваних СКП та розв’язати завдання удосконалення їх роботи і розроблення ефективних енергоощадних СКП, знайти не тільки їх ексергетичний ККД, але й обґрунтувати та підвищити енергоефективність роботи досліджуваних СКП. Досліджено залежність ексергетичного ККД hе та втрат ексергії в основних елементах досліджуваних СКП від визначаючих процес роботи СКП факторів, а саме: температури і вологовмісту навколишнього середовища, внутрішніх температури і вологовмісту повітря чистого приміщення, різниці температур між внутрішнім і припливним повітрям у чистому приміщенні та коефіцієнта трансформації холодильної машини. Запропоновані універсальні залежності для визначення ексергетичного ККД досліджуваних СКП залежно від різних факторів, які впливають на роботу цих СКП. Розроблені пропозиції з вдосконалення роботи елементів центральних прямотечійних СКП чистих приміщень як з камерою зрошення, так і з рекуперативним повітроохолодником, які впливають на зменшення втрат ексергії в них та загальне підвищення ексергетичного ККД цих СКП. Проведен критический анализ использования метода эксергетического исследования процесса работы СКВ, в частности чистых помещений, и приведены требования к качеству воздуха и микроклимата чистых помещений различного назначения. Обоснован выбор объектами исследования процессов работы центральных прямоточных систем кондиционирования воздуха чистых помещений на примере изучения процессов работы с камерой орошения и внедренной СКВ с рекуперативным воздухоохладителем и указана их характеристика. Приведены характеристики исследуемых центральных прямоточных систем кондиционирования воздуха чистых помещений с камерой орошения и рекуперативным воздухоохладителем и определены какие исходные данные нужны для составления их энергетического и эксергетического балансов. Представлено определение удельной эксергии в характерных точках процессов кондиционирования в центральных прямоточных системах для чистых помещений с камерой орошения и рекуперативным воздухоохладителем. Созданы методы составления энергетического и эксергетического балансов исследуемых центральных прямоточных систем кондиционирования воздуха чистых помещений с камерой орошения и рекуперативным воздухоохладителем, которые использованы для всестороннего исследования процессов их работы. Созданы алгоритмы и математические модели работы этих СКВ и, соответственно, разработаны компьютерные программы для осуществления исследований, позволившие выполнить расчетно-количественные эксперименты на математических моделях исследуемых СКП и решить задачу усовершенствования их работы и разработки эффективных энергосберегающих СКВ, найти не только их эксергетический КПД, но и обосновать и повысить энергоэффективность работы исследуемых СКП. Исследована зависимость эксергетического КПД и потерь эксергии в основных элементах исследуемых СКП от определяющих процесс работы СКП факторов, а именно: температуры и влагосодержания окружающей среды, внутренних температуры и влагосодержания воздуха чистого помещения, разницы температур между внутренним и приточным воздухом в чистом помещении и коэффициента трансформации холодильной машины. Приведены диаграммы Грассмана потоков и потерь эксергии для исследуемых систем кондиционирования воздуха, которые дают возможность оценить относительные потери эксергии в ЭТС, понять над уменьшением каких потерь надо работать, а значит получить экономически наиболее выгодный вариант использования избранных систем кондиционирования воздуха. Исходя из анализа диаграмм Грассмана для избранной центральной прямоточной СКВ с камерой орошения, которая обслуживает чистое помещение, установлено, что для повышения эксергетического КПД этой СКВ нужно уменьшить потери эксергии на получение холодной воды в холодильной машине, на транспортировку холодной воды в камеру орошения и в вентиляторе на транспортировку воздуха. Исходя из анализа диаграмм Грассмана для исследуемой центральной прямоточной СКВ с рекуперативным воздухоохладителем, обслуживающей операционные чистые комнаты, установлено, что для повышения эксергетического КПД этой СКВ нужно уменьшить потери эксергии в холодильной машине, на транспортировку воздуха приточным вентилятором кондиционера и вентилятором вытяжной установки. Получены расчетные формулы для определения эксергетического КПД исследуемых СКП в зависимости от температуры и влагосодержания наружного воздуха, в зависимости от температуры и влагосодержания внутреннего воздуха, в зависимости от разницы температур между внутренним и приточным воздухом и влагосодержания наружного воздуха, в зависимости от разницы температур между внутренним и приточным воздухом, в зависимости от коэффициента трансформации холодильной машины и температуры наружного воздуха. Точность расчетных значений по полученным формулам приемлема. Приведены методика и приборы, применявшиеся для экспериментальных исследований на внедренной центральной прямоточной СКВ операционных чистых комнат, результаты экспериментальных исследований на этой СКВ, подтверждена адекватность проведенных на инновационной математической исследовательской компьютерной модели этой СКВ теоретических исследований. Относительная погрешность, определенная по эксергетическому КПД исследуемой СКВ, составляет 3,8%, что находиться в допустимых пределах и свидетельствует об адекватности разработанной математической модели. Предложены универсальные зависимости для определения ексергетического КПД исследуемых СКВ в зависимости от различных факторов, которые влияют на работу этих СКВ. Разработаны предложения по совершенствованию работы элементов центральных прямоточных СКВ чистых помещений как с камерой орошения, так и с рекуперативным воздухоохладителем, которые влияют на уменьшение потерь эксергии в них и общее повышение эксергетического КПД этих СКВ. The new approach to installing exergy saving exploitation of air conditioning systems (ACS) on the example of central straight flow ACS for cleanrooms with the air washer and with recuperative air cooler, which is based on using modern method of thermodynamic analysis − exergetic, has been done. Algorithms and mathematical models of work of these ACS was created and, accordingly, the computer programs were designed which gave opportunity to make computational and quantitative experiments on the mathematical models of investigated systems and solve the task of improving of their work and development of effective energy saving ACS, not to only find their exergetic output-input ratio (OIR), but to prove and raise energy effectiveness of work of investigated ACS. The dependence of exergetic OIR and exergy losses is in the main elements of investigated ACS on factors that are determinants of their work, that are: temperature and moisture content of environment, internal temperature and moisture content air of cleanroom; temperature difference between internal and supplied air in the cleanroom and coefficient of transformation of refrigerator machine, has been investigated. The universal dependences for gaining of exergetic OIR of investigated ACS, depending of different factors which have influence on these ACS work, has been proposed. Propositions about improving the work of elements of central straight flow ACS for cleanrooms with air washer and with recuperative air cooler have influence on decreasing of their exergy losses and general increasing of exergetic OIR of these ACS, has been designed.Item Залежність ексергетичного ККД систем кондиціювання повітря від внутрішньої температури в чистих приміщеннях(Видавництво Львівської політехніки, 2015) Гарасим, Д. І.; Лабай, В. Й.У сучасних технологіях, пов’язаних з перетворенням енергії, а саме у системах кондиціювання повітря, важливе місце займають обладнання і процеси, об’єктивна оцінка ступеня енергетичної досконалості яких може бути встановлена тільки на основі їх термодинамічного аналізу. Класичний апарат цієї науки часто виявляється недостатнім для виконання нових завдань; необхідний не тільки його подальший розвиток, але й поєднання з елементами системного підходу та економіки. Наведено інноваційну математичну дослідницьку модель центральної прямоте- чійної системи кондиціювання повітря чистого приміщення з метою комп’ютерного оцінювання її енергетичної ефективності на основі ексергетичного ККД залежно від різних факторів, що впливають на її роботу. Завдяки цій моделі отримано залежність ексергетичного ККД e h вибраної системи кондиціювання від параметрів внутрішнього повітря, а саме: температури tв і вологовмісту d в . Встановлено, що вплив вологовмісту d в на ексергетичний ККД е h системи є незначним. Показано, що цю систему кондиціювання повітря бажано використовувати за вищих температур внутрішнього повітря, а саме, наприклад, tв = 30 °С, що дасть можливість отримати найвищий ексергетичний ККД е h , а значить отримати економічно найвигідніший варіант використання вибраної системи кондиціювання повітря. In modern technologies, which are related to energy transformation, namely in the air conditioning systems, important place are occupied by equipment and processes, the objective estimation of value of its energy perfection can be defined only on the basis of thermodynamic analysis. Classic apparatus of this science is often insufficient to solve new tasks; it is necessary not only to its further development, but its combination with the elements of a systematic approach and economy.Innovation mathematical research model of the central straight flow air conditioning system for cleanroom in order to computer’s estimation its energy effective by virtue of exergetic output-input ratio depending on different factors, which have influence on its work, was described in this article. The dependence of exergetic output-input ratio for chosen air conditioning system е h on parameters of indoor air, namely temperature tin and moisture content din was defined thanks to this model. It is found, that the effect of moisture content din on exergetic output-input ratio е h of the system is minor. It is shown that the chosen air conditioning system should be preferably used at higher indoor air temperatures, namely, for example tin = 30 °С, that will give the opportunity to gain the highest exergetic output-input ratio е h , which means to gain the most advantageous economical variant of exploitation of chosen air conditioning system.