The operation mode of single-stage current transformer with open secondary circuit

dc.citation.conferenceLitteris et Artibus
dc.contributor.affiliationLviv Polytechnic National Universityuk_UA
dc.contributor.authorFerensovych, Roman
dc.coverage.countryUAuk_UA
dc.coverage.placenameLvivuk_UA
dc.date.accessioned2018-04-20T13:10:44Z
dc.date.available2018-04-20T13:10:44Z
dc.date.issued2016
dc.description.abstractThe operation mode of current transformer with open secondary circuit is emergency and is accompanied by the appearance on the terminals of its secondary winding overvoltages, which are dangerous for secondary equipment and attending personnel. In the paper analysis of operation mode of single-stage current transformer type TV-35 (ТВ-35) after disconnection of its secondary circuit is carried out. The influence of active losses in magnetic core of current transformer TV-35 (ТВ-35) on the values of its secondary overvoltages is investigated.uk_UA
dc.format.pages175-176
dc.identifier.citationFerensovych R. The operation mode of single-stage current transformer with open secondary circuit / Roman Ferensovych // Litteris et Artibus : proceedings of the 6th International youth science forum, November 24–26, 2016, Lviv, Ukraine / Lviv Polytechnic National University. – Lviv : Lviv Polytechnic Publishing House, 2016. – P. 175–176. – Bibliography: 7 titles.uk_UA
dc.identifier.urihttps://ena.lpnu.ua/handle/ntb/40736
dc.language.isoenuk_UA
dc.publisherLviv Polytechnic Publishing Houseuk_UA
dc.relation.referencesen[1] Bachurin N. I. Transformatory toka: raschety i konstrukcii [“Current transformers: calculations and constructions”], M.; L.: Jenergija Publ., 1964, pp. 90–100. [2] Koshmider A. Perenaprjazhenija na vtorichnyh obmotkah transformatorov toka pri nasyshhenii serdechnika [“Overvoltages on secondary windings of current transformers during the magnetic core saturation”], Izvestija vysshih uchebnyh zavedenij: Jelektromehanika – News of higher educational institutions: Electromechanics, 1972, No. 5, pp. 503–506. [3] Gurevich V. I. Zashhita transformatorov toka ot raboty v rezhime s razomknutoj vtorichnoj cep'ju [“Protection of current transformers from operation in the mode with open secondary circuit”], Pro jelektrichestvo – Pro electricity, 2010, No. 3/34, pp. 28–31. [4] Zhurakhivskyi A. V., Kinash B. M., Yatseiko A. Ya., Ferensovych R. Ya. Analiz rezhymiv roboty vtorynnykh kil transformatoriv strumu za yikh rozkorochennia [“Analysis of operation modes of secondary circuits of current transformers after their disconnection”], Visnyk NU “LP”: Elektroenerhetychni ta elektromekhanichni systemy – Bulletin of LPNU: Electric power and electromechanical systems, 2012, No. 736, pp. 43–49. [5] Zhurakhivskyi A. V., Kens Yu. A., Ferensovych R. Ya. Analiz rezhymu roboty transformatora strumu z rozimknenym vtorynnym kolom metodamy analitychnykh rozrakhunkiv [“Analysis of operation mode of current transformer with open secondary circuit by the methods of analytical calculations”], Visnyk Vinnytskoho politekhnichnoho instytutu – Bulletin of Vinnitsa Polytechnic Institute, 2015, No. 6 (123), pp. 89–94. [6] Kens Yu. A., Ferensovych R. Ya., Diachenko N. B., Sproshchenyi analiz ustalenoho rezhymu roboty odnokaskadnoho transformatora strumu za rozkorochennia yoho vtorynnoi obmotky [“Simplified analysis of steady-state operating mode of a single-stage current transformer after opening its secondary winding”], Visnyk NU “LP”: Elektroenerhetychni ta elektromekhanichni systemy – Bulletin of LPNU: Electric power and electromechanical systems, 2015, No. 834, pp. 26–32. [7] Ravlyk O. M., Hrechyn T. M., Ivanonkiv V. Y. Tsyfrovyi kompleks dlia analizu roboty ta proektuvannia prystroiv releinoho zakhystu i avtomatyky [“Digital complex for operation analysis and designing of relaying and automation devices”], Visnyk DU “LP”: Elektroenerhetychni ta elektromekhanichni systemy – Bulletin of LPSU: Electric power and electromechanical systems, 1997, No. 340, pp. 96–101.uk_UA
dc.subjectcurrent transformeruk_UA
dc.subjectsecondary circuituk_UA
dc.subjectdisconnectionuk_UA
dc.subjectterminals of secondary windinguk_UA
dc.subjecthigh-voltage pulsesuk_UA
dc.subjectovervoltagesuk_UA
dc.subjectmagnetic coreuk_UA
dc.subjectactive lossesuk_UA
dc.titleThe operation mode of single-stage current transformer with open secondary circuituk_UA
dc.typeConference Abstractuk_UA

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
LEA-2016-175-176.pdf
Size:
669.34 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.99 KB
Format:
Item-specific license agreed upon to submission
Description: