dc.description.abstract | The need to ensure the quality of installation of large-sized structures made of tempered glass following European standards is emphasized, the relevance of which is emphasized with the acquisition of the status of a candidate for the EU by our country. This provides access to the construction industry to European manufacturers and exports the products of Ukrainian enterprises abroad. Unification of requirements for both fitting tools and quality control tools during the deployment and operation of large-sized tempered glass products has been ensured. The need to automate measuring operations from the moment of manufacturing tempered glass to the moment of its putting in place at the construction site is substantiated. It is shown that for the automation of measuring operations during the insertion of large-sized panes of tempered glass, it is appropriate to use optical measurement methods. | |
dc.format.extent | 39-43 | |
dc.format.pages | 5 | |
dc.identifier.citation | Yatsyk V. Quality monitoring during installation of large tempered glass structures / Vasyl Yatsyk, Nazar Kurylyak // Measuring Equipment and Metrology. — Lviv : Lviv Politechnic Publishing House, 2023. — Vol 84. — No 4. — P. 39–43. | |
dc.identifier.citationen | Yatsyk V. Quality monitoring during installation of large tempered glass structures / Vasyl Yatsyk, Nazar Kurylyak // Measuring Equipment and Metrology. — Lviv : Lviv Politechnic Publishing House, 2023. — Vol 84. — No 4. — P. 39–43. | |
dc.identifier.doi | doi.org/10.23939/istcmtm2023.04.039 | |
dc.identifier.uri | https://ena.lpnu.ua/handle/ntb/61629 | |
dc.language.iso | en | |
dc.publisher | Видавництво Львівської політехніки | |
dc.publisher | Lviv Politechnic Publishing House | |
dc.relation.ispartof | Вимірювальна техніка та метрологія, 4 (84), 2023 | |
dc.relation.ispartof | Measuring Equipment and Metrology, 4 (84), 2023 | |
dc.relation.references | [1] Global flat glass market value 2020–2030. Published by M. Garside, Jul. 25, 2023 [Online]. Available: https://www.statista.com/statistics/1132697/flat-glass-market-valueworldwide/ | |
dc.relation.references | [2] Osoblyvosti sklinnya suchsnylh vysotnykh budivel. SIMAX, 2023 [Online]. Available: https://zlp.com.ua/ua/blog/ostekleniya-sovremennyh-vysotnyh-zdanij (in Ukrainian) | |
dc.relation.references | [3] The Future of Glass Construction in a Warmer World: A Selection of Glazed but Efficient Projects. Arch Daily, 2023 [Online]. Available: https://www.archdaily.com/987719/the-future-of-glass-construction-in-a-warmerworld-a-selection-of-glazed-but-efficient-projects# | |
dc.relation.references | [4] Glasstec Specialist Article No. 4: Glass in Modern Architecture. Date: 24 Nov. 2020 [Online]. Available: https://www.glassonweb.com/article/glasstec-specialistarticle-no-4-glass-modern-architecture | |
dc.relation.references | [5] Hamid Vossoughi, and Blair Gamracy. Are You Getting What You Paid For?: Quality control techniques for evaluating glazing assemblies July 5, 2013 [Online]. Available: https://www.constructioncanada.net/are-you-getting-whatyou-paid-for-quality-control-techniques-for-evaluatingglazing-assemblies/ | |
dc.relation.references | [6] Chiara Bedon, Claudio Amadio. Numerical assessment of vibration control systems for multi-hazard design and mitigation of glass curtain walls. Journal of Building Engineering, Vol. 15, January 2018, pp. 1–13 [Online]. Available: https://www.sciencedirect.com/science/article/abs/pii/S2352710217304552 | |
dc.relation.references | [7] Quality Control of Glass Facades. Curtain Wall and PointFixed Systems Carolina Silveira Machado Pereira Costa. Civil Engineering Instituto Superior Técnico, Universidade de Lisboa, Portugal, April 2018 [Online]. Available: https://fenix.tecnico.ulisboa.pt/downloadFile/1970719973967222/Quality_Control_of_Glass_Facade_Ingles.pdf | |
dc.relation.references | [8] Dimension Measurement and Quality Control during the Finishing Process of Large-Size and High-Precision Components. Hindawi Mathematical Problems in Engineering, Vol. 2022, Article ID 3955974, 8 p. [Online]. Available: https://doi.org/10.1155/2022/3955974 | |
dc.relation.references | [9] 3D Quality Control of Glasses to Meet the Tough Specifications. Apr 29, 2022 [Online]. Available: https://www.3dscantech.com/3d-quality-control-of-glasses-to-meet-thetough-specifications/ | |
dc.relation.references | [10] Luigi Rovati, Luca Pollonini, Franco Docchio. A system for the inspection and quality control of glass slabs. The Review of Scientific Instruments, 73(9): 3386–3391. September 2002. DOI: 10.1063/1.1497501 | |
dc.relation.references | [11] Luigi Rovati, Luca Di Cecilia, Stefano Cattini. On the Feasibility of Absolute Distance Measurement by Using Optical Feedback Into a Superluminescent Diode Cavity. IEEE Transactions on Instrumentation and Measurement. PP(99):1-1. Nov. 2019. DOI: 10.1109/TIM.2019.2956421 | |
dc.relation.references | [12] S. Cattini and L. Rovati, “A Review on Guided Optical Feedback in Super-Luminescence Diodes for Metrological Purposes”, in Journal of Lightwave Technology, Vol. 39, No. 12, 3771–3780, 15 June 15, 2021. DOI: 10.1109/JLT.2020.3035565. | |
dc.relation.referencesen | [1] Global flat glass market value 2020–2030. Published by M. Garside, Jul. 25, 2023 [Online]. Available: https://www.statista.com/statistics/1132697/flat-glass-market-valueworldwide/ | |
dc.relation.referencesen | [2] Osoblyvosti sklinnya suchsnylh vysotnykh budivel. SIMAX, 2023 [Online]. Available: https://zlp.com.ua/ua/blog/ostekleniya-sovremennyh-vysotnyh-zdanij (in Ukrainian) | |
dc.relation.referencesen | [3] The Future of Glass Construction in a Warmer World: A Selection of Glazed but Efficient Projects. Arch Daily, 2023 [Online]. Available: https://www.archdaily.com/987719/the-future-of-glass-construction-in-a-warmerworld-a-selection-of-glazed-but-efficient-projects# | |
dc.relation.referencesen | [4] Glasstec Specialist Article No. 4: Glass in Modern Architecture. Date: 24 Nov. 2020 [Online]. Available: https://www.glassonweb.com/article/glasstec-specialistarticle-no-4-glass-modern-architecture | |
dc.relation.referencesen | [5] Hamid Vossoughi, and Blair Gamracy. Are You Getting What You Paid For?: Quality control techniques for evaluating glazing assemblies July 5, 2013 [Online]. Available: https://www.constructioncanada.net/are-you-getting-whatyou-paid-for-quality-control-techniques-for-evaluatingglazing-assemblies/ | |
dc.relation.referencesen | [6] Chiara Bedon, Claudio Amadio. Numerical assessment of vibration control systems for multi-hazard design and mitigation of glass curtain walls. Journal of Building Engineering, Vol. 15, January 2018, pp. 1–13 [Online]. Available: https://www.sciencedirect.com/science/article/abs/pii/S2352710217304552 | |
dc.relation.referencesen | [7] Quality Control of Glass Facades. Curtain Wall and PointFixed Systems Carolina Silveira Machado Pereira Costa. Civil Engineering Instituto Superior Técnico, Universidade de Lisboa, Portugal, April 2018 [Online]. Available: https://fenix.tecnico.ulisboa.pt/downloadFile/1970719973967222/Quality_Control_of_Glass_Facade_Ingles.pdf | |
dc.relation.referencesen | [8] Dimension Measurement and Quality Control during the Finishing Process of Large-Size and High-Precision Components. Hindawi Mathematical Problems in Engineering, Vol. 2022, Article ID 3955974, 8 p. [Online]. Available: https://doi.org/10.1155/2022/3955974 | |
dc.relation.referencesen | [9] 3D Quality Control of Glasses to Meet the Tough Specifications. Apr 29, 2022 [Online]. Available: https://www.3dscantech.com/3d-quality-control-of-glasses-to-meet-thetough-specifications/ | |
dc.relation.referencesen | [10] Luigi Rovati, Luca Pollonini, Franco Docchio. A system for the inspection and quality control of glass slabs. The Review of Scientific Instruments, 73(9): 3386–3391. September 2002. DOI: 10.1063/1.1497501 | |
dc.relation.referencesen | [11] Luigi Rovati, Luca Di Cecilia, Stefano Cattini. On the Feasibility of Absolute Distance Measurement by Using Optical Feedback Into a Superluminescent Diode Cavity. IEEE Transactions on Instrumentation and Measurement. PP(99):1-1. Nov. 2019. DOI: 10.1109/TIM.2019.2956421 | |
dc.relation.referencesen | [12] S. Cattini and L. Rovati, "A Review on Guided Optical Feedback in Super-Luminescence Diodes for Metrological Purposes", in Journal of Lightwave Technology, Vol. 39, No. 12, 3771–3780, 15 June 15, 2021. DOI: 10.1109/JLT.2020.3035565. | |
dc.relation.uri | https://www.statista.com/statistics/1132697/flat-glass-market-valueworldwide/ | |
dc.relation.uri | https://zlp.com.ua/ua/blog/ostekleniya-sovremennyh-vysotnyh-zdanij | |
dc.relation.uri | https://www.archdaily.com/987719/the-future-of-glass-construction-in-a-warmerworld-a-selection-of-glazed-but-efficient-projects# | |
dc.relation.uri | https://www.glassonweb.com/article/glasstec-specialistarticle-no-4-glass-modern-architecture | |
dc.relation.uri | https://www.constructioncanada.net/are-you-getting-whatyou-paid-for-quality-control-techniques-for-evaluatingglazing-assemblies/ | |
dc.relation.uri | https://www.sciencedirect.com/science/article/abs/pii/S2352710217304552 | |
dc.relation.uri | https://fenix.tecnico.ulisboa.pt/downloadFile/1970719973967222/Quality_Control_of_Glass_Facade_Ingles.pdf | |
dc.relation.uri | https://doi.org/10.1155/2022/3955974 | |
dc.relation.uri | https://www.3dscantech.com/3d-quality-control-of-glasses-to-meet-thetough-specifications/ | |
dc.rights.holder | © Національний університет “Львівська політехніка”, 2023 | |
dc.subject | quality monitoring | |
dc.subject | large-scale constructions | |
dc.subject | standards | |
dc.subject | harmonization | |
dc.subject | tempered glass | |
dc.title | Quality monitoring during installation of large tempered glass structures | |
dc.type | Article |
Files
License bundle
1 - 1 of 1