Probabilistic evaluation of lightning-protection in overhead transmission lines

dc.citation.conferenceLitteris et Artibus
dc.contributor.affiliationLviv Polytechnic National Universityuk_UA
dc.contributor.authorBinkevych, Taras
dc.coverage.countryUAuk_UA
dc.coverage.placenameLvivuk_UA
dc.date.accessioned2018-04-23T07:56:41Z
dc.date.available2018-04-23T07:56:41Z
dc.date.issued2016
dc.description.abstractTraditionally, insulation coordination of power system apparatus relies on deterministic approaches where some conservative voltage stresses are defined and the insulation levels are then adjusted using protective ratios and margins. In the case of lightning stresses, this could easily lead to overinsulation or overdesign and subsequently to an increase in the cost of equipment. On the other hand, insufficient insulation could lead to power system failures with disastrous technical and economic consequences. In this paper we present a formalized method for predicting the lightning-related failure rate of power system equipment. In the probabilistic approach to insulation coordination of power system apparatus we quantify the expected risk of failure under lightning stresses to enable an economically optimized design.uk_UA
dc.format.pages191-192
dc.identifier.citationBinkevych T. Probabilistic evaluation of lightning-protection in overhead transmission lines / Taras Binkevych // Litteris et Artibus : proceedings of the 6th International youth science forum, November 24–26, 2016, Lviv, Ukraine / Lviv Polytechnic National University. – Lviv : Lviv Polytechnic Publishing House, 2016. – P. 191–192. – Bibliography: 9 titles.uk_UA
dc.identifier.urihttps://ena.lpnu.ua/handle/ntb/40746
dc.language.isoenuk_UA
dc.publisherLviv Polytechnic Publishing Houseuk_UA
dc.relation.referencesen[1] Insulation Coordination Application Guide, IEC 71-2 (1996). [2] A.H-S. Ang and W.H. Tang, Probability Concepts in Engineering Planning and Design, Wiley Publ., 1975. [3] R. Lambert, E. Tarasiewicz, A. Xemard and G. Fleury, “Probabilistic Evaluation of Lightning-Related Failure Rate of Power System Apparatus”, IEEE Trans. on power delivery, Vol. 18(2), pp.579-586, 2003. [4] Protection against lightning. P.2 – Risk management for structures and services, IEC 62305-2 (2006). [5] V. Cooray, Lightning Protection, Institution of Engineering and Technology Publ., 2010. [6] M.S. Savic, “Estimation of the surge arrester outage rate caused by lightning overvoltages”, IEEE Trans. on power delivery, Vol. 20(1), pp.116–122, 2005. [7] R. Shariatinasab, F.Ajri and H. Daman-Khorshid, Probabilistic evaluation of failure risk of transmission line surge arresters caused by lightning flash, IET Generation, Transmission & Distribution Publ., 2013. [8] W.A. Chisholm and J.G. Anderson, Lightning and Grounding. EPRI AC Transmission Line Reference Book – 200 kV and Above (3 ed.), EPRI Publ., 2005. [9] I.V. Lishchak “Otsinka nadiinosti skhem hrozozakhystu povitrianykh linii elektroperesylannia” [“Evaluation of reliability of lightning protection circuit overhead lines of electric transmission”], Visnyk NU“LP”: Elektroenerhetychni ta elektromekhanichni systemy – Bulletin of LPNU: Electroenergetics and electromechanics systems, no.785, pp.39-45, 2014.uk_UA
dc.subjectlightning protectionuk_UA
dc.subjectthe transmission lineuk_UA
dc.subjectoverstrainuk_UA
dc.subjectdangerous curve parametersuk_UA
dc.subjectvolt-second characteristicuk_UA
dc.titleProbabilistic evaluation of lightning-protection in overhead transmission linesuk_UA
dc.typeConference Abstractuk_UA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LEA-2016-191-192.pdf
Size:
672.69 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.99 KB
Format:
Item-specific license agreed upon to submission
Description: