Impact of the operating mode of neutral in 35 kV power grids on the arc overvoltages and voltage teasuring transformers

dc.citation.conferenceLitteris et Artibus
dc.contributor.affiliationLviv Polytechnic National Universityuk_UA
dc.contributor.authorYatseyko, Andriy
dc.contributor.authorAndrushko, Volodimir
dc.coverage.countryUAuk_UA
dc.coverage.placenameLvivuk_UA
dc.date.accessioned2018-03-13T09:51:51Z
dc.date.available2018-03-13T09:51:51Z
dc.date.issued2015
dc.description.abstractHas been analyzed possible methods of earthing of neutrals in 35 kV power grid. Among the most common injuries in these electrical system are arc circuits, that is why the dependence of overvoltage multiplicities on the nature of earth arcing and on the method of earth arrangement of electrical system neutral. Given that in 35 kV power grids may arise ferroresonant processes, operation of voltage measuring transformers has been researched during unstable earth arcing.uk_UA
dc.format.pages170-173
dc.identifier.citationYatseyko A. Impact of the operating mode of neutral in 35 kV power grids on the arc overvoltages and voltage teasuring transformers / Andriy Yatseyko, Volodimir Andrushko // Litteris et Artibus : proceedings of the 5th International youth science forum, November 26–28, 2015, Lviv, Ukraine / Lviv Polytechnic National University. – Lviv : Lviv Polytechnic Publishing House, 2015. – P. 170–173. – Bibliography: 6 titles.uk_UA
dc.identifier.urihttps://ena.lpnu.ua/handle/ntb/39607
dc.language.isoenuk_UA
dc.publisherLviv Polytechnic Publishing Houseuk_UA
dc.relation.referencesen[1] E. F. Tsapenko, “Zamykanija na zemlju v setjah 6-35 kV” [“Earth faults in networks of 6-35 kV”], Moscow, Russia: Energoatomizdat Publ., 1986, 128 pages. [2] “Pravyla ulashtuvannia elektroustanovok” [“Regulations of electrical installations arrangement”], 2-nd edit., rev. and enlarged. Kharkiv, Ukraine: Fort Publ., 2009, 736 pages. [3] O. Ravluk, T. Grechin and V. Ivankiv, “Tsyfrovyi kompleks dlia analizu roboty ta proektuvannia prystroiv releinoho zakhystu i avtomatyky (prohrama RE)” [“In digital system for analysis and design of relay protection and automation control”], Visnyk DU “Lvivska politekhnika” – Bulletin SU “Lviv Polytechnic”, no.340, pp.96-101, 1997. [4] G. A. Evdokunin, S. V. Gudilin and А. А. Korepanov, “Vybor sposoba zazemlenija nejtrali v setjah 6-10 kV” [“The choice of method of neutral earthing in networks 6-10 kV”], Jelektrichestvo – Electricity, no.12, pp.8-22, 1998. [5] G. A. Evdokunin and G. А. Tiler, “Sovremennaja vakuumnaja kommutacionnaja tehnika dlja setej srednego naprjazhenija (tehnicheskie preimushhestva i jekspluatacionnye harakteristiki)” [“Modern vacuum switching technology for medium voltage networks (technical advantages and operating characteristics)”], SPb, Russia: Sizova M.P. Publ., 2000, 114 pages. [6] F. A. Gyndullyn et al., “Perenaprjazhenija v setjah 6-35 kV” [“Overvoltage in networks 6-35 kV”], Moscow, Russia: Energoatomizdat Publ., 1989, 192 pages.uk_UA
dc.subjectpower griduk_UA
dc.subjectarc overvoltageuk_UA
dc.subjectdigital modeluk_UA
dc.subjectinsulated neutraluk_UA
dc.subjectresonant-earth neutraluk_UA
dc.subjectovervoltage ratiouk_UA
dc.subjectresistance-earth neutraluk_UA
dc.subjectvoltage transformersuk_UA
dc.titleImpact of the operating mode of neutral in 35 kV power grids on the arc overvoltages and voltage teasuring transformersuk_UA
dc.typeConference Abstractuk_UA

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
57-170-173.pdf
Size:
459.24 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.99 KB
Format:
Item-specific license agreed upon to submission
Description: