Автоматичне калібрування лінійності ЦАП з ваговою надлишковістю

No Thumbnail Available

Date

2014

Journal Title

Journal ISSN

Volume Title

Publisher

Видавництво Львівської політехніки

Abstract

Описано метод та структурну організацію автоматичного калібрування лінійності АЦП з ваговою надлишковістю на основі побітової арифметики. The bit-serial arithmetic based method and structure organization of automatic linearity calibration for ADC with weight redundancy are described in this article. The calibration characteristics of ADC with order-by-order indemnification are used for defining the accuracy of an analog-to-digital signal conversion. This method was developed for ADC with selfcalibration which works in gold 1-proportion numerical system. The method is based on comparison of results of two ADC, which converts the same signal. Various pipeline bit-serial arithmetic devices in this numerical system were developed by the authors, which was described in scientific publications and can be used for calculation of linearity deviation in such way.

Description

Keywords

АЦП, самокалібрування, побітова арифметика, золота 1-пропорція, DAC, self-calibration, bit-serial arithmetic, gold 1-proportion

Citation

Азаров О. Д. Автоматичне калібрування лінійності ЦАП з ваговою надлишковістю / О. Д. Азаров, О. І. Черняк // Вісник Національного університету «Львівська політехніка». – 2014. – № 792 : Теплоенергетика. Інженерія довкілля. Автоматизація. – С. 28–31. – Бібліографія: 6 назв.