Ferroresonant processes in 10 kV power grids and there control

dc.citation.conferenceLitteris et Artibus
dc.contributor.affiliationLviv Polytechnic National Universityuk_UA
dc.contributor.authorYatseyko, Andriy
dc.contributor.authorHyrska, Kateryna
dc.coverage.countryUAuk_UA
dc.coverage.placenameLvivuk_UA
dc.date.accessioned2018-03-13T09:34:40Z
dc.date.available2018-03-13T09:34:40Z
dc.date.issued2015
dc.description.abstractThe problem of ferroresonance processes in power gris with isolated neutral was reviewed. Conditions of the existence of such phenomena and basic principles of theis control were establihed. A new approaches of protection for 10 kV electric systems from ferroresonant processes were given. The research was conducted using digital simulation and reasons for offered protection methods were defined.uk_UA
dc.format.pages164-167
dc.identifier.citationYatseyko A. Ferroresonant processes in 10 kV power grids and there control / Andriy Yatseyko, Kateryna Hyrska // Litteris et Artibus : proceedings of the 5th International youth science forum, November 26–28, 2015, Lviv, Ukraine / Lviv Polytechnic National University. – Lviv : Lviv Polytechnic Publishing House, 2015. – P. 164–167. – Bibliography: 5 titles.uk_UA
dc.identifier.urihttps://ena.lpnu.ua/handle/ntb/39605
dc.language.isoenuk_UA
dc.publisherLviv Polytechnic Publishing Houseuk_UA
dc.relation.referencesen[1] A. N. Zhurahivskyy et al., “Ferorezonansni protsesy v elektromerezhakh 10 kV z riznotypnymy transformatoramy napruhy” [“Ferroresonance processes in l0 kV power grids with different voltage transformers”], Tekhnichna elektrodynamika – Technical electrodynamics, no.2, pp.73-78, 2010. [2] Y. Saenko and A. Popov, “Poshkodzhennia vymiriuvalnykh transformatoriv napruhy v elektromerezhakh z malymy strumamy zamykannia na zemliu” [“Damage measuring voltage transformers in power grid with currents with low ground fault”], Visnyk Kharkivskoho NTU silskoho hospodarstva im. Petra Vasylenka. Tekhnichni nauky – Journal of Kharkov NTU of Agriculture Petro Vasilenko. Technical sciences, no.2(23), pp.253-258, 2011. [3] F. H. Khalilov et al., “Zashhita setej 6-35 kV ot perenaprjazhenij” [“Protecting networks 6-35 kV surge”], Saint Petersburg, Russia: Petersburg Energy Institute for Advanced Studies of the Ministry of Energy of the Russian Federation Publ., 2001, 216 pages. [4] O. Ravluk, T. Grechin and V. Ivankiv, “Tsyfrovyi kompleks dlia analizu roboty ta proektuvannia prystroiv releinoho zakhystu i avtomatyky (prohrama RE)” [“In digital system for analysis and design of relay protection and automation control”], Visnyk DU „Lvivska politekhnika“ – Bulletin SU “Lviv Polytechnic”, no.340, pp.96-101, 1997. [5] The system of protection from voltage transformer ferroresonance processes in power grid with isolated neutral based device NRF-5, guidance manuals, Lviv, 2012, 20 pages.uk_UA
dc.subjectelectric systemsuk_UA
dc.subjectpower gridsuk_UA
dc.subjectferroresonant processesuk_UA
dc.subjectdigital modeluk_UA
dc.subjectisolated neutraluk_UA
dc.subjectvoltage transformersuk_UA
dc.titleFerroresonant processes in 10 kV power grids and there controluk_UA
dc.typeConference Abstractuk_UA

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
55-164-167.pdf
Size:
682.33 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.99 KB
Format:
Item-specific license agreed upon to submission
Description: