Optoelectronic method of estimation of chosen combustion parameters of an individual pulverised coal burner

dc.contributor.authorWojcik, W.
dc.contributor.authorGolec, T.
dc.contributor.authorManak, 1.
dc.contributor.authorSmolarz, 1.
dc.contributor.authorKotyra, A.
dc.contributor.authorKomada, P.
dc.contributor.authorKalita, M.
dc.date.accessioned2016-01-21T13:03:49Z
dc.date.available2016-01-21T13:03:49Z
dc.date.issued2004
dc.description.abstractThere are several tens of burners operating in a power boiler and their control based on averaged and delayed measurements is often not effective enough. The article describes attempts to obtain information about levels of emission of NOx and CO from the signals of the fiber-optic flame monitoring system developed in the Department of Electronics of the Lublin University of Technology. Artificial neural networks are used for estimation of emission. The article contains description of an object and the measurement system as well as results of research of nitrogen oxides and carbon monoxide modelling.uk_UA
dc.identifier.citationOptoelectronic method of estimation of chosen combustion parameters of an individual pulverised coal burner / W. Wojcik, T. Golec, 1. Manak, A. Smolarz, A. Kotyra, P. Komada, M. Kalita // Вісник Національного університету «Львівська політехніка». – 2004. – № 510 : Елементи теорії та прилади твердотілої електроніки. – С. 73–77. – Bibliography: 8 titles.uk_UA
dc.identifier.urihttps://ena.lpnu.ua/handle/ntb/31091
dc.language.isoenuk_UA
dc.publisherВидавництво Національного університету "Львівська політехніка"uk_UA
dc.titleOptoelectronic method of estimation of chosen combustion parameters of an individual pulverised coal burneruk_UA
dc.typeArticleuk_UA

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
16_73-77.pdf
Size:
272.61 KB
Format: