Вимірювальна техніка та метрологія

Permanent URI for this communityhttps://ena.lpnu.ua/handle/ntb/2123

Browse

Search Results

Now showing 1 - 7 of 7
  • Thumbnail Image
    Item
    Direct solution of polynomial regression of order up to 3
    (Видавництво Львівської політехніки, 2022-02-28) Dorozhovets, Mykhaylo; Lviv Polytechnic National University
    This article presents results related to the direct solution of the polynomial regression parameters based on the analytical solving of regression equations. The analytical solution is based on the normalization of the values of independent quantity with equidistance steps. The proposed solution does not need to directly solve a system of polynomial regression equations. The direct expressions to calculate estimators of regression coefficients, their standard deviations, and also standard and expanded deviation of polynomial functions are given. For a given number of measurement points, the parameters of these expressions have the same values independently of the range of input quantity. The proposed solution is illustrated by a numerical example used from a literature source.
  • Thumbnail Image
    Item
    Calibration of quartz electronic stopwatchers comparison method using a digital camera
    (Видавництво Львівської політехніки, 2022-02-28) Meshcheriak, Oleh; Velychko, Oleh; State Enterprise “Ukrmetrteststandard”
    Measurement of time intervals with low accuracy on intervals from a few seconds to several hours or days is relevant for some broad applications in various fields of activity. Such measurements are widely used in the technological processes of various enterprises during the preparation and quality control of the preparation of medicines, during the maintenance of technical equipment and mechanisms, chemical technological processes, etc. For such measurements, manual electronic quartz stopwatches are widely used, which, despite their not too high measurement accuracy, must guarantee users the accuracy of measurements within the tolerance established by the technical documentation, since the risks of using untested measuring equipment are quite high, or generally unacceptable especially in the medical field. The issue of calibrating quartz electronic stopwatches by various methods remains relevant for many of their applications. The article discusses the calibration of quartz electronic stopwatches by the method of comparison using a digital camera. A calibration scheme for stopwatches was developed and a calibration measurement model was created based on the developed calibration scheme. The contribution of each component of the measurement model to the calibration result and the corresponding uncertainties of the model components were determined. The measurement uncertainty budget was made based on the proposed stopwatch calibration model. The influence of the most significant influential values on the accuracy of measurement results was analyzed. The content of quantitative and qualitative correction indicators, which must be taken into account during calibration to achieve the highest accuracy of measurements, is revealed. The method of calibrating stopwatches described in the article can be used in calibration laboratories that have the appropriate equipment and standards.
  • Thumbnail Image
    Item
    Analysis of calorimetric method of measurement of natural gas calorific value
    (Lviv Politechnic Publishing House, 2021) Motalo Andriy; Motalo Vasyl
    The article considers the current methods of measuring the calorific value of natural gas which are valid in the up to-date gasometry. The procedure for measuring the gross and net volume-basis specific calorific value of natural gas by the calorimetric method is analyzed. It is shown that to increase the accuracy and validity of measurement results, the experiment to determine the values of gross and net volume-basis specific calorific should be performed for at least 5 samples of the investigated gas. A methodology for estimating the accuracy of measuring the gross and net volume-basis specific calorific values of natural gas by the calorimetric method by finding estimates of the uncertainty of the obtained measurement results taking into account both random and systematic influencing factors are developed. The uncertainty budgets for measuring the gross and net volume basis-specific calorific values of natural gas have been developed for the practical implementation of the methodology. The results of experimental studies of samples of one of the natural gas fields are given and the objective values of the gross and net volume basis specific calorific with estimates of extended uncertainty are obtained.
  • Thumbnail Image
    Item
    Multipurpose measurement models for adjustment by the least-squares method
    (Видавництво Львівської політехніки, 2021-02-23) Kuzmenko, Iuriy; Samoilenko, Olexandr; Tsiporenko, Serhiy; State Enterprise “Ukrmetrteststandard”
    The development of multipurpose measurement models is the precondition for software development for simultaneous adjustment of the large scope and complicated combinations of the measurement results by the least-squares method. Multipurpose measurement models for software can be a helpful tool for processing the final measurement results provided by different measurement methods applying the mentioned software; processing the measurement results of measurement standards comparisons, interlaboratory comparison, and calibration procedures; estimating the additive and multiplicative systematic components of measurement errors and their uncertainty; processing complicated combinations by binding or linking up of the interlaboratory comparison and calibration results in the time; simultaneous processing of the measurement results obtained by various methods e.g. by the method of direct measurements and comparisons; fast-changing the multipurpose measurement models from linear to non-linear type. Processing of the results by software based on the multipurpose measurement model algorithm can help to established a comprehensive measurement traceability network by pooling the single traceability chains.
  • Thumbnail Image
    Item
    Еталон одиниці ультразвукового тиску у водному середовищі
    (Видавництво Львівської політехніки, 2019-02-28) Дувіряк, Д. В.; Шпак, О. В.; Паракуда, В. В.; Duviriak, Dariia; Shpak, Oleksandr; Parakuda, Vasyl; ДП НДІ “Система”; SE R&DI “Systema”
    Проаналізовано актуальність створення в Україні первинного еталона одиниці ультразвукового тиску у водному середовищі в діапазоні частот від 0,5 МГц до 10 МГц, зумовлену необхідністю метрологічного забезпечення чинного ультразвукового медичного обладнання та проведення процедур оцінки відповідності вимогам технічного регламенту щодо медичних виробів для введення їх в експлуатацію. Перелік параметрів акустичного виходу ультразвукового медичного обладнання стандартизований Міжнародною електротехнічною комісією (ІЕС), зокрема параметри ультразвукового діагностичного обладнання нормують відповідно до ІЕС 61157, а параметри фізіо- терапевтичного обладнання – ІЕС 61689. У статті проаналізовано методи відтворення ультразвукового тиску у водному середовищі в діапазоні частот від 0,5 МГц до 10 МГц, вибрано метод для створення первинного еталона одиниці ультразвукового тиску у водному середовищі – метод взаємності із двома перетворювачами. Наведено математичну модель методу відтворення одиниці ультразвукового тиску, функціональну схему еталона з описом роботи основних елементів та подано загальний вигляд створеного первинного еталона. Окремо вказано основні вимоги до допоміжного ультразвукового перетворювача, який застосовують відповідно до вибраного методу. Також наведено вимоги до вимірювального середовища – води. Описано експериментальні дослідження метрологічних властивостей еталона та наведено порівняння отриманих метрологічних характеристик створеного еталона з характеристиками відповідних зарубіжних еталонів.
  • Thumbnail Image
    Item
    Аналіз методик верифікації та калібрування засобів вимірювальної техніки
    (Видавництво Львівської політехніки, 2019-02-26) Мотало, В. П.; Motalo, Vasyl; Національний університет “Львівська політехніка”; Lviv Polytechnic National University
    Проаналізовано проблематику реалізації метрологічного підтверджування засобів вимірювальної техніки відповідно до міжнародних вимог і можливі напрями їх вирішення. Розглянуто як спільні характеристики, так і певні відмінності основних методик метрологічного підтверджування ЗВТ – верифікації і калібрування, а також сфери їх застосування. Проаналізовано методи верифікації та калібрування ЗВТ, а також точність та достовірність результатів метрологічного підтверджування ЗВТ.
  • Thumbnail Image
    Item
    Uncertainties of multivariable indirect measurements of dc electrical circuits
    (Видавництво Львівської політехніки, 2018-02-26) Варша, З.; Пухальський, Я.; Warsza, Zygmunt; Puchalski, Jacek; Науково-дослідний інститут автоматизації та вимірювань, Польща; Головний метрологічний офіс, Польща; Industrial Research Institute of Automation and Measurements, Warszawa; Central Metrology Office, Warszawa
    Висвітлено особливості опрацювання результатів вимірювання за допомогою непрямої багатопараметрової вимірювальної системи. Розглянуто три випадки вивчення непевностей вимірювання. Запропоновано поширити векторний метод оцінювання непевностей вимірювання, поданий у додатку 2 до GUM, на статистичне описання параметрів точності непрямої багатопараметрової вимірювальної системи. Подано формули для коваріантної матриці відносних непевностей векторного межеранда. Матриця непевностей для випадку декількох електричних систем вимірювання на постійному струмі підлягає аналізу. Інакше кажучи, аналізують непрямі вимірювання електричного опору за допомогою моста Вінстона, причому вимірювання внутрішніх опорів зіркової конфігурації з оцінюванням непевності струму напруги живлення підлягають розгляду. Наведені формули для абсолютної та відносної непевностей, а також їх коефіцієнти кореляції. Основний висновок такий: описання параметрів точності багатопараметрової вимірювальної системи відносними непевностями іноді краще порівняно із подібним описанням на основі абсолютних непевностей, що й повинно враховуватись під час розгляду.