Computational Problems of Electrical Engineering
Permanent URI for this communityhttps://ena.lpnu.ua/handle/ntb/12128
Науково-технічний журнал
Засновник і видавець Національний університет «Львівська політехніка». Виходить двічі на рік з 2011 року.
Browse
2 results
Search Results
Item “Fringing” current influence on results ofmeasuring cross-section area of liquid flow by a conductive sensor(Publishing House of Lviv Polytechnic National University, 2014) Voitiuk, Volodymyr; Trushakov, Dmytro; Rendzinyak, SerhiyThe work presents the results of theoretical research and simulation of “fringing” current distribution and its influence on the output signal of a conductive sensor which is used as a measuring device for determining a cross-sectional area of liquid flow (in particular, milk flow) and consists of electrodes placed on the walls of the dielectric tube with a rectangular cross-section. As a result, an influence coefficient of fringing current on measurement results has been obtained, which determines the deviation of the total current of the sensor from the current of the same sensor without taking into account the fringing current. It has been determined the cross-sectional area of the current flow where fringing current significantly influences the value of the sensor output signal. This allows determining the minimum length of the conductive sensor. The results of research are presented in graphical and numerical forms. Наведено результати теоретичних досліджень та моделювання ступеня впливу струмів розсіювання на вихідний сигнал кондуктивного сенсору, що складаються з електродів, розташованих на стінках діелектричної труби прямокутного перерізу, який використовується як вимірювач площі поперечного перерізу потоку рідини (молока). У результаті отримано значення коефіцієнта впливу струмів розсіювання на результати вимірювання, який визначає відхилення величини загального струму сенсора порівняно з величиною струму, що протікає по поперечному перерізу, який збігається з поверхнею електродів, тобто основного струму. Загальний струм сенсора визначається як сума основного струму та струму розсіювання. Визначено відстань, що відлічується по осьовій лінії труби від границі протікання основного струму, від краю електродів сенсора, на якій струми розтікання спричиняють відчутний вплив на величину вихідного струму сенсора, що дає змогу визначити мінімальну довжину сенсора. Результати дослідження подано в графічній та числовій формі.Item A measuring transducer in the system of technical diagnosis of overhead lines icing in electrical distribution networks(Publishing House of Lviv Polytechnic National University, 2015) Kozlovskyi, Oleksandr; Trushakov, Dmytro; Rendzinyak, SerhiyThe existing diagnosis systems of icing on wires of overhead power lines use imperfect diagnosis algorithms and icing sensors. In the paper, the schematic diagram of a measuring icing transducer and structure of its sensor based on uninsulated wires of overhead power lines of А and АС types have been substantiated. The sensor consists of a main electrode in the form of an isolated aluminum strand twisted around the central one and a secondary electrode in the form of an adjacent strand. The resistanse between the electrodes is measured; if the electrodes are isolated, the resistance btewwn them is close to infinity. If there is ice between the electrodes, its resistance is determined by the resistance of the ice. The threshold values of ohmic resistance of the sensor (АС-50 type wire) have been calculated for two types of ice depositions: rime and hoar frost. To ensure a reduced length of the sensor, additional main electrodes are used. It is shown that, by fixed measurement accuracy, the sensor length depends on the number of additional electrodes, central angles between them being equal. Using the proposed measuring transducer in a diagnosis system allows the formation of rime and hoar frost depositions to be forecasted and registered at an early stage, and thus enables to increase the ice melting effectiveness. Існуючі системи діагностування обледеніння (у вигляді утворення ожеледних та паморозних відкладень на проводах повітряних ліній розподільних електромереж використовують недосконалі алгоритми діагностування та сенсори обледеніння. Обґрунтовано структурну схему вимірювального перетворювача для діагностування явища обледеніння та конструкцію його сенсора на базі неізольованих проводів повітряних ліній електропередачі типів А, АС. Конструктивно сенсор являє собою основний електрод у вигляді ізольованої дротини, скрученої навколо центральної, та допоміжний електрод у вигляді сусідньої дротини. Для зменшення довжини сенсора можна збільшити кількість основних електродів. Розраховано порогові значення омічного опору сенсора (провід АС-50) для двох видів ожеледно-паморозевих відкладень: паморозі та ожеледі. Показано, що довжина сенсора, за незмінної точності вимірювань, залежить від кількості допоміжних електродів, при рівності центральних кутів між ними. Застосування запропонованого вимірювального перетворювача у складі системи технічного діагностування дає змогу прогнозувати та фіксувати утворення ожеледно-паморозевих відкладень на ранній стадії і таким чином підвищити ефективність проведення плавки ожеледі.